The size of any regular outdoor wood furnace or any EPA outdoor gasification furnace should be matched to the requirements. All wood furnace manufacturers use either a BTU rating or square footage capabilities. Since the BTU’s in wood vary, the only true way to state maximum heating capabilities of an outdoor wood furnace in square feet. Here are some guidelines to follow:

Base Calculations
In Canada and Northern USA, start your calculations by using 75% of the stated maximum square footage. This is usually a safe place to start under most conditions. When you exceed this amount, be very careful in your calculations. Upgrade to the next size of any outdoor furnace or EPA outdoor wood gasifying furnace long before you reach the maximum heating capability.

Ceiling Height
Calculations of an outdoor wood furnace heating ability is always based on new construction with an 8 ft. ceiling. For a 16 foot ceiling consider adding up 40% to 50% to that area.

Basement & Upstairs
VERY IMPORTANT Also add the square footage of the basement and the upstairs and any other area to be heated.

Building Age
The older the building the less likely it is to have adequate insulation and be airtight. New R2000 buildings have lower heating demands on the outdoor water furnace.

Distance From Furnace to Buildings
The better the underground insulation then the less impact from long distances. Some of the better underground insulations loose almost no heat in 300 feet.

Easy Rule of Thumb Solution
Once you pass the 3/4 mark on square footage, consider moving up to the next larger size of outdoor furnace. Over sizing never hurts; it will allow more time between fills. You do not want to regret buying a small wood stove that is maximized.

Problems Caused by Under Sizing
When filling a properly sized outdoor boiler, you would normally add wood either morning and evening, or once per day, depending on the season. If the firebox is too small and it is a really cold night and you are using lots of heat, and most of the fire wood is already burned up; your outdoor furnace may not be able to continue making more BTU per hour than you are using. When you are low on wood in a high demand time, the temperature of the water in your outdoor furnace may drop from 180F to 160F to 140F to 120F. Anytime you are 150F or lower in any outdoor furnace the difference in the temperature between the water jacket and the firebox will cause condensation in the firebox. This condensation can cause steam in the firebox, which will cause a poor fire burn. It may seem like you are gobbling up wood and getting very little heat. Sometimes the quickest way to recover from this is to turn off the circulator until the water reaches 180F, and then the temperature will stay up there. With a properly sized firebox, this will never happen.

If you have an older home, multiple buildings, or simply would like to know for sure give us your measurements and we will calculate the proper sizing for you. Simple fill out our contact form and we’ll reach you to go over the information.

Outdoor wood furnace news – The Good and Bad

admin | August 30th, 2010 | No Comments »

newsProposed Wood Furnace Ban Provokes Controversy
Rep. Richard Roy, D-Milford, had to halt an exchange over a ban on outdoor wood furnaces between the president of Environment and Human Health, Inc. and Rep. Bryan Hurlburt, D-Tolland, during a public hearing before the legislature’s Environment Committee Monday. [read more]

Outdoor wood boiler rules being drafted
The King George Board of Supervisors last week unanimously voted to give the go-ahead for a formal review of draft rules to address the use of outdoor wood boilers in King George. The issue has been under review since last fall, after complaints had come to light about some users of wood boilers who have them installed close to property lines, creating a smoke nuisance for near neighbors. [read more]

W. Hartford joins Granby in banning outdoor wood furnaces
In a vote last Tuesday evening, West Hartford town officials became the 11th Connecticut town to ban outdoor wood-burning furnaces. They join the Town of Granby in making this decision. [read more]

Lancaster City Council won’t crack down on burning
The Lancaster City Council will not regulate or ban the use of outdoor wood-fired furnaces, despite a recent complaint from a local business owner. Skyview Drive-In owner Walt Effinger, who addressed the City Council at its meeting Aug. 9, said a nearby outdoor boiler… [read more]

Foes of outdoor furnaces vow to turn up the heat
A push to ban outdoor wood-burning furnaces appears to be picking up steam. The issue has divided health advocates, who cite studies showing the dangers wood smoke, and farmers, who rely on the devices to heat homes, barns, greenhouses and outbuildings. [read more]